TVT-SECUR“H”术式治疗女性压力性尿失禁短期疗效报告及文献分析

陈晓松, 欧彤文, 张建, 等. TVT-SECUR“H”术式治疗女性压力性尿失禁短期疗效报告及文献分析[J]. 临床泌尿外科杂志, 2013, 28(5): 364-366,370.
引用本文: 陈晓松, 欧彤文, 张建, 等. TVT-SECUR“H”术式治疗女性压力性尿失禁短期疗效报告及文献分析[J]. 临床泌尿外科杂志, 2013, 28(5): 364-366,370.
CHEN Xiaosong, OU Tongwen, ZHANG Jian, et al. A short-term curative effect report and literature analysis of TVT-SECUR “H” procedure for the treatment of female stress urinary incontinence[J]. J Clin Urol, 2013, 28(5): 364-366,370.
Citation: CHEN Xiaosong, OU Tongwen, ZHANG Jian, et al. A short-term curative effect report and literature analysis of TVT-SECUR “H” procedure for the treatment of female stress urinary incontinence[J]. J Clin Urol, 2013, 28(5): 364-366,370.

TVT-SECUR“H”术式治疗女性压力性尿失禁短期疗效报告及文献分析

详细信息
    通讯作者: 张建,E-mail:cxsyzhjdsh@sina.com
  • 中图分类号: R699.7

A short-term curative effect report and literature analysis of TVT-SECUR “H” procedure for the treatment of female stress urinary incontinence

More Information
  • 目的:探讨新近开发的单切口尿道中段吊带术(TVT-SECUR)治疗女性压力性尿失禁(SUI)的有效性及手术关键。方法:回顾分析2009~2011年共16例SUI患者资料,ALPP均大于60 cmH2O,施行"H"术式,术中以示指引导保持穿刺方向及穿刺层面。术后24、48及72 h采用直观模拟量表(VAS)对患者术后早期切口疼痛进行评价,3个月时门诊随访评判疗效及并发症。结果:本研究中16例手术平均24 min,无尿道膀胱损伤,无阴道穿孔,无吊带暴露、无明显肢体运动障碍及局部血肿形成,无明确伤口感染及排斥反应发生。术后24小时VAS为(2.6±1.5),术后3个月随访时总有效率为93.7%(15/16),一过性并发症包括排尿困难(2/16),急迫性尿失禁(5/16),泌尿系感染(4/16)。结论:TVT-SECUR"H"术式治疗SUI,操作简单,安全有效,并发症少。术中手指触摸引导有利于确定穿刺方向及深度,对保证术后疗效和减少并发症具有重要意义。
  • 加载中
  • [1]

    McCracken G R, Henderson N A, Ashe R G. Five year follow-up comparing tension-free vaginal tape and colposuspension[J]. Ulster Med J, 2007, 76:146-149.

    [2]

    Kilonzo M, Vale L, Stearns S C, et al. Cost effectiveness of tension-free vaginal tape for the surgical management of female stress incontinence[J]. Int J Technol Assess Health Care, 2004, 20:455-463.

    [3]

    朱兰, 王巍. 提高压力性尿失禁手术安全性的建议[J]. 中华外科杂志, 2008, 46(20):1523-1524.

    [4]

    García S L, Ramírez D L, Rey J R, et al. Complications of polypropylene mesh for the treatment of female pelvic floor disorders[J]. Arch Esp Urol, 2011, 64:620-628.

    [5]

    Tincello D G, Botha T, Grier D, et al. The TVT Worldwide Observational Registry for Long-Term Data:safety and efficacy of suburethral sling insertion approaches for stress urinary incontinence in women[J]. J Urol, 2011, 186:2310-2315.

    [6]

    Chae H D, Kim S R, Jeon G H, et al. A comparative study of outside-in and inside-out transobturator tape procedures for stress urinary incontinence[J]. Gynecol Obstet Invest, 2010, 70:200-205.

    [7]

    Dietz H P, Barry C, Lim Y N, et al. Two-dimensional and three-dimensional ultrasound imaging of suburethral slings[J]. Ultrasound Obstet Gynecol, 2005, 26:175-179.

    [8]

    Hinoul P, Vanormelingen L, Roovers JP, et al. Anatomical variability in the trajectory of the inside-out transobturator vaginal tape technique (TVT-O)[J]. Int Urogynecol J Pelvic Floor Dysfunct, 2007, 18:1201-1206.

    [9]

    Bonnet P, Waltregny D, Reul O, et al. Transobturator vaginal tape inside out for the surgical treatment of female stress urinary incontinence:anatomical considerations[J]. J Urol, 2005, 173:1223-1228.

    [10]

    Hubka P, Masata J, Nanka O, et al. Anatomical relationship and fixation of tension-free vaginal tape Secur[J]. Int Urogynecol J Pelvic Floor Dysfunct, 2009, 20:681-688.

    [11]

    Hinoul P, Vervest H A, den Boon J, et al. A randomized, controlled trial comparing an innovative single incision sling with an established transobturator sling to treat female stress urinary incontinence[J]. J Urol, 2011, 185:1356-1362.

    [12]

    Walsh C A. TVT-Secur mini-sling for stress urinary incontinence:a review of outcomes at 12 months[J]. BJU Int, 2011, 108:652-657.

    [13]

    Lee K S, Lee Y S, Seo J T, et al. A prospective multicenter randomized comparative study between the U- and H-type methods of the TVT SECUR procedure for the treatment of female stress urinary incontinence:1-year follow-up[J]. Eur Urol, 2010, 57:973-979.

    [14]

    Martan A, Svabík K, Masata J, et al. Correlation between changes in ultrasound measurements and clinical curative effect of tension-free vaginal tape-SECUR* procedure[J]. Int Urogynecol J Pelvic Floor Dysfunct, 2009, 20:533-539.

    [15]

    Shin Y S, Cha J S, Cheon M W, et al. Efficacy and safety of the TVT-SECUR® and impact on quality of life in women with stress urinary incontinence:a 2-year follow-up[J]. Korean J Urol, 2011, 52:335-339.

    [16]

    王怡君, 黄奕良, 陈映鹤, 等. TVT-S治疗女性压力性尿失禁的疗效和安全性分析[J]. 中华泌尿外科杂志, 2011, 32(2):130-133.

    [17]

    Araco F, Gravante G, Sorge R, et al. Sedation with local versus general anesthesia for the tension-free vaginal tape Secur hammock procedure[J]. Int J Gynaecol Obstet, 2011, 113:108-111.

    [18]

    Hubka P, Nanka O, Martan A, et al. Anatomical study of position of the TVT-O to the obturator nerve influenced by the position of the legs during the procedure:based upon findings at formalin-embalmed and fresh-frozen bodies[J]. Arch Gynecol Obstet, 2011, 284:901-905.

    [19]

    Hubka P, Nanka O, Martan A, et al. TVT-S in the U position-anatomical study[J]. Int Urogynecol J, 2011, 22:241-246.

    [20]

    Hubka P, Masata J, Nanka O, et al. Anatomical relationship and fixation of tension-free vaginal tape Secur[J]. Int Urogynecol J Pelvic Floor Dysfunct, 2009, 20:681-688.

    [21]

    Nyyssönen V, Talvensaari-Mattila A, Santala M. Intravaginal slingplasty sling is associated with increased risk of vaginal erosion[J]. Acta Obstet Gynecol Scand, 2009, 88:1222-1226.

    [22]

    Tincello D G, Botha T, Grier D, et al. The TVT Worldwide Observational Registry for Long-Term Data:safety and efficacy of suburethral sling insertion approaches for stress urinary incontinence in women[J]. J Urol, 2011, 186:2310-2315.

    [23]

    Oliveira R, Botelho F, Silva P, et al. Exploratory study assessing efficacy and complications of TVT-O, TVT-Secur, and Mini-Arc:results at 12-month follow-up[J]. Eur Urol, 2011, 59:940-944.

  • 加载中
计量
  • 文章访问数:  81
  • PDF下载数:  141
  • 施引文献:  0
出版历程
收稿日期:  2012-08-12

目录